Heat Pump Payback in Burleson, TX

Heat pump vs. gas furnace in Burleson, TX

In Burleson, the extra upfront cost technically comes back, just not before the equipment wears out. Against a like-for-like gas furnace and AC swap, going electric costs $5,500 more up front here. Lower bills claw that back: about $338 saved annually, for a payback of roughly 16.3 years. That's a technicality, not a recommendation, for anyone actually living in Burleson.

Checking a different city

Landed on Burleson by mistake, or want to compare it against somewhere else? Search the other 3206 cities below.

3206 US cities, each with its own weather station and state energy prices.

Burleson's weather, in the numbers that matter

Degree days tell the story here: Burleson racks up 1826 heating degree days each year (base 65°F), and summers are severe enough that cooling can dominate the annual bill, with 2994 cooling degree days on the cooling side. Sizing runs off the design temperature, not the average day: 14°F here (coldest 2024 reading 10.4°F), which works out to a seasonal COP of 3.04 for the cold-climate class of unit this climate calls for. Mild on average, but the occasional cold snap is what sizes the equipment: at a 14°F design temperature Burleson falls just under the 25°F line where a standard heat pump starts leaning on resistance backup, so the model prices a cold-climate unit to be safe. These numbers come from Fort Worth Spinks Airport, the closest NOAA station, 3.6 miles out.

What it actually costs to run, year to year

Modelled on a typical 2000-square-foot house, the heat pump draws about 1,521 kWh a year to keep it warm, plus cooling, for a combined electric bill near $658 a year. The gas furnace it replaces burns roughly 19 Mcf a year at $19.42 per Mcf here, for a running cost near $996 a year including the old AC (electricity here runs 16.15¢/kWh). Priced as a standalone purchase, with a working furnace ripped out early, payback would take longer than the 15-year equipment life. Measured against the like-for-like replacement instead, a household here ends 15 years $429 behind.

What would change Burleson's answer

Gas would only overtake the heat pump in Burleson if electricity rose past 190.9¢/kWh from 16.15¢, or gas fell under $1.64 per Mcf from $19.42. A useful quote test for Burleson: the heat pump is worth it within a decade if it costs less than $3,380 more than replacing the furnace and AC, and within 7 years if the gap is under $2,366.

Electric resistance heat in Burleson, compared

Plenty of homes in Burleson heat with electricity alone, no gas line involved. Against electric-resistance heat, baseboard or an electric furnace, both 100% efficient but still just resistance, the case for switching gets stronger here. Switching saves about $715 a year here, a heat pump moving heat rather than generating it needs far less electricity than resistance coils, so the extra $10,000 spent up front comes back in about 14 years.

Burleson against the rest of the country

Among 3206 cities, Burleson's winter puts it at rank 2524 for severity, while its size puts it at rank 732 for population, 1 in both cases being the extreme. That's the mildest third of cities covered, where utility rates carry more of the answer than climate does.

Deciding what's next in Burleson, TX

Burleson, Texas is home to about 56,253 people, and the figures above are the same ones a local HVAC contractor uses to size and quote a system, this site doesn't guess where a real quote would land, it just tells you whether it's worth asking for one. In Burleson, nothing is lost by holding off until the current equipment genuinely fails.

Line up a few local HVAC quotes before you decide.

Where Burleson's figure comes from

Every constant behind this page, the 3.04 seasonal COP, the degree-day corrections, the equipment costs, is documented in the methodology guide. Burleson's 14°F design temperature is below the 25°F line, which is why a cold-climate unit is the right call here, see what that changes in the cold-climate unit guide.